FTTH Drop Cable
Part Code: 80CDE

DESCRIPTION
FTTH Drop cable construction is that the optical fiber unit is positioned in the center: Two parallel strength members are placed at the two sides and then outer sheath.
Key Features
- Complies to ANSI/TIA-568.3-D, ISO/IEC11801, IEC 60794-1-2: 2017, ITU-T G.657.A1
- Good crush resistance ensured by parallel strength members
- Low smoke, zero halogen and flame retardant sheath
- Simple structure, light weight and high practicability
SPECIFICATION
Fiber Specifications
Fiber Standard : ITU-T G.657.A1 Mode Field Diameter : 9.0±0.4µm(1310nm) : 10.1±0.5 µm(1550nm) Cladding Diameter : 124.8±1.0µm Cladding Non -circularity : ≤0.7% Core- Cladding Concentricity error : ≤0.5µm Coating Diameter : 245±7µm Coating Non-Circularity : ≤6.0 Coating-Cladding Concentricity error : ≤12.0µm Cable cutoff wavelength : ≤1260nm Attenuation (Max.) : @1310nm ≤0.4dB/km : @1550nm ≤0.3dB/km Macro-Bending Loss : @1turnx10mm radius @1550nm : ≤0.75dB : @1turnx10mm radius @1625nm : ≤1.5dB Cable Specifications
Fiber Count : 1 ~ 4 Parallel strength Member Dimension : 0.5mm Parallel strength Member Material : FRP Additional Strength Member : Steel rod ( Applicable for Outdoor ) Jacket Dimension : 3.0±0.1mm x 2.0±0.1mm Jacket Material : LSZH Jacket Color : Black Mechanical and Environmental Specifications
Tension Long Term : 40N Tension Short Term : 80N Crush Long Term : 500N/10cm Crush Short Term : 1000N/10cm Minimum bend radius (Dynamic) : 20D (mm) Minimum bend radius (Static) : 10D (mm) Installation Temperature : -20 to +60 degree Celsius Operating Temperature : -40 to +70 degree Celsius Storage Temperature : -40 to +70 degree Celsius